The electron measures analyzer of network of vector of Rohde&Schwarz ZVL6 6G of analyzer of network of 4-8GHz of instrument network analyzer | Lord and 9KHz of the Ci that use watt come 6GHz
Rohde%26amp;Schwarz ZVL6 6G矢量收集分析仪|罗德与施瓦茨 9KHz-6GHz
品牌:罗德与施瓦茨Rohde%26amp;Schwarz
机能特点:
|
频率规模
|
9kHz至3GHz/6 GHz(典型值为5kHz)
|
|
测量时候(201个测量点,以校准的双端口)
|
%26lt;75ms
|
|
数据传输(201个测量点)
|
|
|
在100Mbit/sLAN上经由过程RSIB
|
1.5ms
|
|
10Hz测量带宽时的动静规模
|
%26gt;115 dB,典型值为123 dB
|
|
输出功率
|
%26gt;0 dBm, 典型值为+10 dBm
|
|
测量带宽
|
10Hz至500kHz(1/2/5步)
|
|
分量(不带电池)
|
%26lt;7kg(15.43lb)
|
|
通道、图表和轨迹线的数目
|
%26gt;100
|
|
每条轨迹线的测量点数目
|
2至4001
|
|
操作系统
|
WindowsXP
|
频谱分析
|
频率规模
|
9kHz至3GHz/6 GHz
|
|
频率误差
|
1*10-6
|
|
带有R%26amp;S%26reg;FSL-B4选项
|
1*10-7
|
|
分辨率带宽
|
|
|
尺度
|
300Hz至10MHz (1/3步),零档时为20 MHz
|
|
带有R%26amp;S%26reg;FSL-B7选项
|
(1Hz)10Hz至10 MHz (1/3步)
|
|
视频带宽
|
10Hz至MHz
|
|
I/Q解调带宽
|
20MHz
|
|
500 MHz时的典型相位噪声
|
-100dBc(1Hz),10 kHz载波偏置
|
|
显示的平均噪声级别
|
|
|
1GHz时,不带前置放大器
|
%26lt;-140dBm(1Hz)
|
|
1GHz时,带前置放大器
|
%26lt;-156 dBm(1Hz),典型值为-163dBm(1Hz)
|
|
IP3
|
%26gt;+5 dBm, 典型值为+12 dBm
|
|
检测器
|
正/负峰值、主动峰值、RMS、准峰值、平均值、取样
|
|
电平测量误差(95%置信电平)
|
%26lt;0.5dB
|
如果阁下需要了解该设备详细情况,请致电0755-83610849联系我们的销售工程师,或发送电子邮件到lscaiyi@163.com索取产品规格书。
设备保修与备件更换条件
自用户购买之日本公司所有新产品均按照原厂质保条例提供3包服务;二手仪器提供7天退还和180天免费质保。
免除免费保修义务
本公司的产品实行保修年限之内的有限保修。属于下列情况的设备(包括部件)故障或损坏,不在有限保修之列(尽管产品在保修期之内),本公司不承担免费保修义务:
设备、部件已经超出了保修期;
客户未按照说明书要求,错误安装,保管及使用而造成的设备(包括部件)故障或损坏;
由非 本公司授权机构、人员拆卸而造成的设备(包括部件)故障或损坏;
因意外因素或者人为原因(包括如操作失误、划伤、搬运、磕碰、输入不合适的电压和电流等)导致的设备(包括部件)故障或损坏;
因自然灾害等不可抗力(如地震、火灾等)原因造成的产品故障或损坏;
Analyzer of network of vector of Rohde&Schwarz ZVL6 6G | Lord and 9KHz of the Ci that use watt come 6GHz
Brand: Lord and Rohde&Schwarz of the Ci that use watt
Function characteristic:
|
Frequency limits |
9kHz is 5kHz) to cost of 3GHz/6 GHz(type |
|
Measure time (201 measurement point, pair of port with calibration) |
<75ms |
|
Number is defeated as it is said (201 measurement point) |
|
|
RSIB is passed on 100Mbit/sLAN |
1.5ms |
|
The trends when 10Hz measures bandwidth limits |
> 115 DB, typical cost is 123 DB |
|
Output power |
> 0 DBm, typical cost is + 10 DBm |
|
Measure bandwidth |
10Hz to 500kHz(1/2/5 pace) |
|
Weight (do not carry battery) |
<7kg(15.43lb) |
|
The amount of chart and passageway, trochoid |
> 100 |
|
Every measurement point amount of trochoid |
2 to 4001 |
|
Operating system |
WindowsXP |
Spectrum analysis
|
Frequency limits |
9kHz comes 3GHz/6 GHz |
|
Frequency error |
1*10- 6
|
|
Contain R&S®FSL-B4 option |
1*10- 7
|
|
Resolution bandwidth |
|
|
Standard |
300Hz comes) of 10MHz (1/3 pace, 20 MHz is when 0 archives |
|
Contain R&S®FSL-B7 option |
(1Hz)10Hz to pace of 10 MHz (1/3) |
|
Video is taken wide |
10Hz comes MHz |
|
I/Q demodulation bandwidth |
20MHz |
|
500The model when MHz is phasic noise |
- 100dBc(1Hz) , 10 KHz carrier wave slants buy |
|
Sound level of indication average a confusion of voices is fastened |
|
|
When 1GHz, not belt preamplifier |
<-140dBm(1Hz) |
|
When 1GHz, belt preamplifier |
<-156 DBm(1Hz) , typical cost is - 163dBm(1Hz) |
|
IP3 |
> + 5 DBm, typical cost is + 12 DBm |
|
Detector |
/ negative peak value, automatic peak value, RMS, exact peak value, average, sampling |
|
N measures an error (95% believe n) |
<0.5dB |
If Your Exllency needs to know this equipment detailed circumstance, call 0755-83610849 to contact our sale engineer please, or send email to ask for product standards book to Lscaiyi@163.com.