网站首页新闻资讯技术资讯 商品分类全部商品关于我们 联系我们繁體中文


本站仪器查找   

高级搜索
用户登录 用户注册 忘记密码
banner
二手仪器 EMI/EMS测试系统MR2400|EMC/EMI/EMS测试|EMI/EMS测试预认证|EMC认证前期评估系统|EMC/EMI/EMS分析仪
查看更多

二手仪器 EMI/EMS测试系统MR2400|EMC/EMI/EMS测试|EMI/EMS测试预认证|EMC认证前期评估系统|EMC/EMI/EMS分析仪

商品型号: 日本迈可尼斯|MICRONIX
商品品牌:
计量单位: 台(套)
商品简介: EMC/EMI/EMS测试仪器 EMI/EMS测试系统MR2400|EMC/EMI/EMS测试|EMI/EMS测试预认证|EMC认证前期评估系统|EMC/EMI/EMS分析仪
参考价格: 0.00
售前服务:0755-83610849               即时沟通:   与我在线交流
购买 收藏
EMC/EMI/EMS checks instrument EMI/EMS to check systematic MR2400 | EMC/EMI/EMS checks | EMI/EMS checks beforehand attestation | EMC attestation early days evaluates a system | EMC/EMI/EMS analyzer

EMI/EMS测试系统MR2400|EMC/EMI/EMS测试|EMI/EMS测试预认证|EMC认证前期评估系统|EMC/EMI/EMS分析仪

The system combining the EMI test system MR2300 and the EMS test systemMR2350 is the EMC test system MR2400. The PC software is MAS240.
The price of MR2400 becomes much lower than purchasing MR2300 and MR2350 separately because the anechoic box MY5310/5310S/5410 and the broadband antenna MAN101/102 are common to two systems.

EMI测试系统MR2300|EMC/EMI测试|EMI测试预认证|EMC认证前期评估系统|EMC/EMI分析仪

★对于EMl测试

EMC测试由 EMl测试和EMS测试组成。EMl测试用于对从EUT(被测最安装)开释的喷射性干扰噪声或传导性干扰噪声是否超出划定的尺度值进行评估。设 立该尺度值的目标在于,包管EUT操作不会对其他行动措施的操作或无线通信造成显著的干扰。
另一标的目标,EMS测试也用于对周边的电磁波是否会引起EUT发生误动作进行评估。
按照本公司的经验或一般情况来说,与EMI无关的问题数目或采纳办法的时候凡是为EMS的5~10倍。也就是说,假如EMl测试经由过程,则能够说EMC测试已经实现了80----90%。是以,MR2300是专用于EMl测试的系统。



★什么是MR2300
一般来说,利用EMl电波暗室的正式测试需要很长时候且会发生费用。而反复屡次采纳问题对策并进行正式测试,则更破费时问和费 用。MR2300系统运作的同的在于事先解决问题,进行以Precompliance为方针的利用,从而可将正式测试削减到1~2次。理论Precompliance用EMl测试系统以前就有,但就包括电波暗室的总系统统而言,MR2300则为世界初创。在当前TV电波或无线通信行动措施电波长短纷歧的情况下,没有电波暗室是无法进行EMl测试的。
★MR2300性能
可进行2种EMl测试

1、喷射性干扰噪声测试
利用电波暗室和宽频天线,可在30MHz~3GHz的频带规模内进行测量。
2、传导性干扰噪声测试
利用LISN(线路阻抗不乱收集)可在1 50kHz~30MHz的频带规模内进行测量。
可确定噪声发生源
3、EUT 内PCB:磁场测量
经由过程利用选购件磁场探头CP-2S进行印刷电路板磁场测量,可确定干扰噪声的发生源。
★MR2300的拿手
MR23 00是集本公司频谱分析仪技术、电波暗室技术及天线技术于一身的综合系统。
1、世界首个一总体EMI测试试系统
天线、EMl用频谱分析仪、LISN、EMl用PC软件等自不必说,但就连电波暗室也具备的总体测试系统而言,MR2300不啻为世界初创。 此外,作为解决问题的 工具,还备有磁场探头(选购件)。根柢不需要增添任何额在行动措施。
2、本公司开辟的超尘型宽频天线
本公司开辟出578(W)%26times;401(H)%26times;250(D)mm(MAN101,不包括底板) 的超小型、30M Hz~3GHz的宽频天线。小型化天线使得电波暗室的小型化成为可能。
3、大、中、小等4种电波暗室
备有小型EUT用MY531 0/S、中型EUT用MY5310SU及人型EUT用MY5410。MY5310/S配备有承重10kg/ 直径220mm的转台,MY5310配备有承重50k9/直径500mm的转台,MY5410配备有承重1 00kg/直径756mm的转台。
4、整个系统的校准
整个系统经由过程MSA3 3 8E和PC软件来抵偿宽频天线的天线增益、LISN的衰减量,以及向3m法的转换等。用户只要间接读取PC画面中的测量成果即可。
5、依据尺度
依据CISPR 11l(classA/B、group1l)、CISPR22(classA/B)、EN55011(classA/B、group 1)、EN55022(classA/B)、VCCI(classA/B)、FCC part15 subpartB(classA/B)等尺度。

EMS测试系统MR2350|EMC/EMS测试|EMS测试预认证|EMC认证前期评估系统|EMC/EMS分析仪

★对于EMS测试


EMC测试分EMl测试和EMS测试两部门。EMl测试用于对从EUT(被测量安装)开释的喷射性干扰噪声或传导性干扰噪声是否超出划定的尺度值进行评估。设立该尺度值的目标在于,包管EUT操作不会对其他行动措施的操作或无线通信造成显著的干扰。上述辐射测试可操纵EMl测试系统MR2300进行。
另一方面,EMS测试也用于对周边的电磁波是否会引起EUT发生误动作进行评估。该辐射抗干扰性测试可操纵本系统Precom-pliance用EMS测试系统MR2350进行。操纵设置在电波暗室内的EUT监控摄像头,可在PC画面上掌控EUT是否引起误动作。当然,这仅限于可操纵画面等视觉体例判定EUT误动作的情况。
★EMI+EMS测试系统MR2400
E M c测试系统M R 2400是由EMI测试的M R2 300与EM S测试的M R 2 3 5 0组合而成的系统。P C软件为M A S 2 4 0。
电波暗室:MY5310/5310S与宽频天线MAN 101是通用于MR2300和MR2350,是以,MR2400没有包括这部门价钱。
★MR2350的拿手
1、 l、3、1 0V/m的电场强度
可发生1 V/m、3 V/m、1 0 V/m共3个级别以及任意(1~1 0 V/m)的电场强度。

2 、操纵EUT监控摄像头检测误动作
可操纵设置在电波暗室内的摄像头确认辐射电磁波是否导致EUT 误动作。图像显示在PC画面上。

3 、本公司开辟的超小型宽频天线
本公司开辟出 578(W)%26times;401(H)%26times;250(D)mm(不含底板)的超小型、30MHz--3GHz的宽频天线。

4 、可在MR2400长进行EMI+EMS测试
可操纵由EMl测试系统的MR2300与EMS测试系统的MR2350组合而成的MR2400进行EMC(EMI+EMS)测试。

5、 l台PC可节制整个系统
EMl测试、EMS测试,以及EUT监控摄像头、电动转台(选购件)等所有节制皆由1台PC实施。

6 、电动转台(工厂选购件)
电动转台尺寸为220mm¢,承重为15kg。 由PC节制。

※也可用于EMl测试系统MR2300。
备有MAS20T或MAS240T的PC软件。



如果阁下需要了解该设备详细情况,请致电0755-83610849联系我们的销售工程师,或发送电子邮件到lscaiyi@163.com索取产品规格书。



设备保修与备件更换条件

自用户购买之日本公司所有新产品均按照原厂质保条例提供3包服务;二手仪器提供7天退还和180天免费质保。

免除免费保修义务

本公司的产品实行保修年限之内的有限保修。属于下列情况的设备(包括部件)故障或损坏,不在有限保修之列(尽管产品在保修期之内),本公司不承担免费保修义务:
设备、部件已经超出了保修期;
客户未按照说明书要求,错误安装,保管及使用而造成的设备(包括部件)故障或损坏;
由非 本公司授权机构、人员拆卸而造成的设备(包括部件)故障或损坏;
因意外因素或者人为原因(包括如操作失误、划伤、搬运、磕碰、输入不合适的电压和电流等)导致的设备(包括部件)故障或损坏;
因自然灾害等不可抗力(如地震、火灾等)原因造成的产品故障或损坏;

EMI/EMS checks systematic MR2400 | EMC/EMI/EMS checks | EMI/EMS checks beforehand attestation | EMC attestation early days evaluates a system | EMC/EMI/EMS analyzer

The System Combining The EMI Test System MR2300 And The EMS Test SystemMR2350 Is The EMC Test System MR2400. The PC Software Is MAS240.
The Price Of MR2400 Becomes Much Lower Than Purchasing MR2300 And MR2350 Separately Because The Anechoic Box MY5310/5310S/5410 And The Broadband Antenna MAN101/102 Are Common To Two Systems.

EMI checks systematic MR2300 | EMC/EMI checks | EMI checks beforehand attestation | EMC attestation early days evaluates a system | EMC/EMI analyzer

★ checks about EMl

EMC test is formed by EMl test and EMS test. EMl test is used at be opposite to be measured from EUT(most device) the mark fiducial value that whether the radioactivity that release disturbs noise or conductibility interference noise exceeds a regulation undertakes evaluating. Establish the purpose of this mark fiducial value to depend on, assure EUT operation to won't cause remarkable interference to the operation of other equipment or wireless communication.
       Another direction, EMS test also is used at whether can causing EUT to produce misoperation to undertake evaluating to circumjacent electromagnetic wave.
       For the experience according to our company or general situation, the 5 ~ that are EMS normally with the issue amount that EMI concerns or the time that take step 10 times. That is to say, if EMl test is passed, can say EMC checked to had been finished 80----90 % . Accordingly, MR2300 is special the system that tests at EMl.

 

  
         
★ what is MR2300
    Generally speaking, the formal test of darkroom of use EMl electric wave needs for a long time and can produce cost. And take problem the way to deal with a situation for many times repeatedly and have formal test, more beautiful take time asks and charge. MR2300 system runs those who be the same as depend on solving a problem beforehand, undertake is the use of the target with Precompliance, can reduce formal test 1 ~ 2 times thereby. Actual Precompliance checks a system to have before with EMl, but the overall system that includes electric wave darkroom, MR2300 is world initiate. Below current TV electric wave or environment of stagger of freely of electric wave of wireless communication equipment, doing not have electric wave darkroom cannot undertake EMl checks.
★ MR2300 function
Can undertake 2 kinds of EMl check

1, radioactivity interference noise checks
     Darkroom of use electric wave and broadband antenna, can undertake metrical inside the frequency band limits of 30MHz ~ 3GHz.
2, conductibility interference noise checks
     Impedance of use LISN(circuitry stabilizes a network) can undertake metrical inside the frequency band limits of 30MHz of 1 50kHz ~ .
Can decide noise produces a source
3, the PCB inside EUT: Magnetic field is measured
     Through using a choose and buy CP-2S of magnetic field probe undertakes printed circuit board magnetic field is measured, can disturb the hair source of student of noise certainly.
The specialty of ★ MR2300
MR23 00 is collect technology of technology of analyzer of our company spectrum, electric wave darkroom and aerial technology the comprehensive system at a suit.
1, test of EMI of body of first all of world tries a system
Aerial, EMl uses PC software to wait to need not say oneself with spectrum analyzer, LISN, EMl, but the overall test system that also has even electric wave darkroom, MR2300 not less than is world initiate. Additional, as the tool that solves a problem, return probe of stock magnetic field (choose and buy) . Need to add any additional equipment far from.
2, our company develop exceed dirt broadband antenna
Our company develop a 578(W)×401(H)×250(D)mm(MAN101, do not include motherboard) the broadband antenna that exceeds 3GHz of small-sized, 30M Hz ~ . Miniaturization antenna makes the miniaturization of electric wave darkroom becomes a possibility.
3, big, medium, small wait for darkroom of 4 kinds of electric wave
Stock is small-sized EUT uses MY5310SU and person EUT to use MY5410 with S of MY531 0 / , medium-sized EUT. MY5310 / S matchs stock to bearing the revolving stage of 220mm of 10kg / diameter, MY5310 matchs stock to bearing the revolving stage of 500mm of 50k9 / diameter, MY5410 matchs stock to bearing the revolving stage of 756mm of diameter of 1 00kg / .
4, the calibration of whole system
Whole system compensates the attenuation of the aerial gain of broadband antenna, LISN through MSA3 3 8E and PC software, and wait to the changeover of 3m law. The user needs to read the measurement in picture extraction PC directly only result can.
5, basis standard
The standard such as B) of / of B) of / of B) of / of B of / of B) of / of B of / of basis CISPR 11l(classA, Group1l) , CISPR22(classA, EN55011(classA, Group 1) , EN55022(classA, VCCI(classA, FCC Part15 SubpartB(classA.
 

 

EMS checks systematic MR2350 | EMC/EMS checks | EMS checks beforehand attestation | EMC attestation early days evaluates a system | EMC/EMS analyzer

 

★ checks about EMS

 
       EMC checks minute of EMl test and EMS to test two parts. EMl test is used at be opposite from EUT(by measurement unit) the mark fiducial value that whether the radioactivity that release disturbs noise or conductibility interference noise exceeds a regulation undertakes evaluating. Establish the purpose of this mark fiducial value to depend on, assure EUT operation to won't cause remarkable interference to the operation of other equipment or wireless communication. Afore-mentioned radiation tests can use EMl to check systematic MR2300 to undertake.
       On the other hand, EMS test also is used at whether can causing EUT to produce misoperation to undertake evaluating to circumjacent electromagnetic wave. Sexual test can use this radiate interference rejection this systematic Precom-pliance checks systematic MR2350 to undertake with EMS. Use a setting to be photographed in the EUT monitoring inside electric wave darkroom like the head, EUT can accuse to whether cause misoperation in the palm on PC picture. Of course, this is confined to the case that can use the visual means such as the picture to judge EUT misoperation.
★ EMI+EMS checks systematic MR2400
The system that the M R 2 3 5 0 that M R 2400 of system of test of E M C is the M R2 300 that checks by EMI and EM S test is combined and becomes. P C software is M A S 2 4 0.
Electric wave darkroom: MY5310 / 5310S and broadband antenna MAN 101 are general at MR2300 and MR2350, accordingly, MR2400 did not include this share price.
The specialty of ★ MR2350
1, L, 3, the electric field intensity of 1 0V/m
Can produce M of / of 1 V/m, 3 V/m, 1 0 V in all 3 level and random (the electric field intensity of M) of / of 1 ~ 1 0 V.

2, use EUT monitoring to photograph detect like the head misoperation
Can use a setting inside electric wave darkroom photograph affirm like the head whether radiation electromagnetic wave brings about EUT misoperation. Image shows go up in PC picture.

Of 3, our company development exceed small-sized and broadband antenna
Our company develop a 578(W)×401(H)×250(D)mm(not to contain motherboard) exceed small-sized, 30MHz- - the broadband antenna of 3GHz.

4, can undertake on MR2400 EMI+EMS checks
The MR2400 that the MR2350 that can use the MR2300 that tests a system by EMl and EMS test system is combined and becomes undertakes EMC(EMI+EMS) checks.

5, L stage PC is controallable whole system
EMl test, EMS checks, and EUT monitoring is photographed like head, dynamoelectric revolving stage (choose and buy) wait for all control to all be carried out by a PC.

6, dynamoelectric revolving stage (factory choose and buy)
Dimension of dynamoelectric revolving stage is 220mm ¢ , bearing for 15kg. By PC control.
 

※ also can be used at EMl to check systematic MR2300.
The PC software of stock MAS20T or MAS240T.
 

 

 

 

 



If Your Exllency needs to know this equipment detailed circumstance, call 0755-83610849 to contact our sale engineer please, or send email to ask for product standards book to Lscaiyi@163.com.
顾客平均评分: ,共有0位顾客进行了评分和评论, 点此登录发表评论,分享购物心得
显示:       查找:
请先点此登录再进行评论





相关商品