常备现货.TOS8870A AC耐压/绝缘电阻测试仪.可连续进行耐压绝缘电阻试验
TOS8870A是一款兼备耐压测试仪和绝缘电阻计的测试仪,可连续进行耐压试验和绝缘
电阻试验。(设定AUTO ACW→IR、AUTO IR→ACW、MANU.ACW、MANU.IR的
任一方)。耐压试验可以在最大输出5kV、输出容量500VA(AC专用)下进行电子设
备和电子部件的耐压试验。此外,绝缘电阻试验具有2个测量范围:500V/1000MΩ和
1000V/2000MΩ。(输出特性符合JIS C 1302-1994)
特点
■在一道工序中进行耐压试验和绝缘阻试验
■耐压试验和绝缘电阻试验,其PASS-FAIL判定均
采用窗口比较器方式
■通过测试/复位操作的远程控制功能,对应试验
的自动化和省力化
■信号输出为TEST ON信号/PASS信号/READY
信号/耐压试验和绝缘电阻试验的FAIL警报
■零通电开关
■耐压试验为5kV-100mA的500VA容量
■测试/复位操作的远程控制功能
■ 绝缘电阻试验具有2 个测量范围: 5 0 0V/
1000MΩ和1000V/2000MΩ
■搭载有放电功能
■数字计时器999秒
规格
●耐试验:施加电压[AC0kV%26#12316;2.5kV/5kV]、
漏损电流上限基准值[0.5mA%26#12316;100mA (0.5mA
%26#12316;25.5mA 0.5mA梯级)]、电压计[2.5kV/
5kV f.s、精度±1.5% f.s(在环境温度为15℃%26#12316;
35℃、正弦波的条件下)] ●绝缘电阻试验:测
量电压[DC500V:1M%26#12316;1000MΩ/DC1000V:
2M%26#12316;2000MΩ]、测量精度[第1有效测量范围:
指示值的±5%、第2有效测量范围:指示值的±
10%] ●电源:AC100V±10% ●随附测试引
线:TL01-TOS
尺寸(最大尺寸)/重量
430(435)W×132(155)H×370(440)Dmm/约23kg
Compression of.TOS8870A AC of standing merchandise on hand / insulation resistance instrument. Can undertake compression insulation resistance experiments continuously
TOS8870A is one has both compression instrument and insulation resistance plan instrument, can have compression experiment and insulation continuously
Resistor experiments. (of ACW of → of IR of → of set AUTO ACW, AUTO IR, MANU.ACW, MANU.IR
Hold the post of one party) . Compression experiment can be in 500VA of capacity of 5kV of the biggest output, output (AC is special) next undertaking that the electron is set
The compression of equipment and electronic component experiments. In addition, insulation resistance experiment has 2 to measure range: Ω of 500V / 1000M and
Ω of 1000V / 2000M. (output character accords with JIS C 1302-1994)
Characteristic
■ undertake in a working procedure compression experiment and insulation block experiment
■ compression experiment and insulation resistance experiment, its PASS-FAIL decides all
Use window comparator means
■ the long-range control function that handles through checking / restoration, correspondence experiments
automation and save labour are changed
■ signal output is READY of / of signal of PASS of / of TEST ON signal
Experiment of signal / compression and the FAIL alarm that insulation resistance experiments
■ 0 electrify switch
■ the 500VA capacity that compression experiment is 5kV-100mA
■ test / the long-range control function that restoration handles
■ insulation resistance experiment has 2 to measure range: / of 5 0 0V
1000M Ω and Ω of 1000V / 2000M
■ embark have discharge function
■ digital clock 999 seconds
Norms
● is able to bear or endure experiment: Bring to bear on voltage [AC0kV〜2.5kV / 5kV] ,
Upper limit of leakage caustic electric current is standard value [0.5mA〜100mA (0.5mA
〜25.5mA 0.5mA stair) ] , voltage plan [2.5kV /
± of 5kV F.s, precision 1.5% F.s (15 ℃ are in environmental temperature 〜
Below the condition of wave of 35 ℃ , sine) ] ● insulation resistance experiment: Measure
Quantity voltage [DC500V: DC1000V of 1M〜1000M Ω / :
2M〜2000M Ω ] , measure precision [the 1st measure range effectively:
The 5 % of ± of indicated value, the 2nd measure range effectively: The ± of indicated value
10 % ] ● power source: ● of 10 % follows AC100V ± add a test to bring
Line: TL01-TOS
Dimension (the largest size) / weight
430 (435) W × 132 (155) H × 370 (440) Dmm / makes an appointment with 23kg
| 顾客平均评分: | ,共有0位顾客进行了评分和评论, | 点此登录发表评论,分享购物心得 |